Updates and rollback
An update made things worse
Undo it. The update dialog on the station (admin) shows the copy it kept before the last update, with Revert to previous version. The station re-installs that copy and restarts its services, and keeps a copy of the version being left so the revert can itself be undone. Going back to an older version drops the settings added since it, the first time it saves - which is why setup's Start page offers Download current parameters before a run.
"This update cannot be reverted" or "the station did not keep a copy"
No copy is available: a development build, a station coming off a build older than the rollback feature, or no room. The copy must leave 256 MB free on the station's storage, because a full card is a station that can no longer save its own configuration. Free space, then update again. These warnings stay up after a successful update on purpose - they are what you need to read afterwards.
The uploaded file was refused
The station reads the version out of the archive and, when that version is published, checks the file's signature. A published version whose bytes differ is refused and nothing is touched. A file it cannot check - a development build, or a station with no route to the update server - installs with a "not verified" warning when the update is started on that station itself, and on every station that accepts unsigned updates from other machines; otherwise see the next block.
An update sent from another station is refused: signature could not be checked
The station being updated is a pilot's laptop, and the release came from somewhere else - another station's interface, a fleet push, or a browser on a different machine. Such a station installs an update from another machine only when it can check the release's signature, and it could not: the release was never signed, or the station has no internet to fetch the signature for it. Nothing was installed and the station is as it was.
Two ways on. Run the update on that machine itself - open its own interface at
http://127.0.0.1/ and update from there, which this never applies to. Or switch Unsigned updates
from other machines (parameter update_remote_unverified) on (Control > Network > Device
discovery, or the Remote support dialog under What support may do), send the update again,
and switch it off afterwards; on a laptop that switch answers only on the laptop itself, and it goes
off by itself at the next start of Sokil.
A signature that is present and does not match is refused everywhere, whatever that switch says: the file is not the release it says it is. Every other ground station, a repeater included, ships with the switch on and updates and downgrades from a file exactly as before.
The same refusal appears when you update a device behind another station - a Radxa VTX, a repeater, a radio head - from your own page: the device, not the station in between, judges the file. Run the update on the device's own station, or switch Unsigned updates from other machines on at the device itself (its own page, or its station's page).
A device behind another station: "Station's copy" is not offered
The Station's copy tab names the station next to the device and says why it has nothing to send. No copy - the station keeps none (a fresh SD-card image or a development build). Not the version the station runs - the copy it kept belongs to an earlier release; update that station from the update server or a file first, which also makes a fresh copy. Does not fit this device - the copy is cut down for the station that holds it and lacks something this device needs; use From update server or Upload a file instead. Could not read the device - the station could not ask the device what it needs. The other two tabs stay available in every case.
A device behind another station: "update <station> first"
A station in the chain is older than this interface and does not know how to carry the update. The station next to the device is too old to update a device behind it, or a station in between is too old to pass this update on. Nothing was changed. Update the named station - from this station if it is directly reachable, or through the first station for the one behind it - and then offer the device again; the dialog does so by itself when it started that update.
An uploaded package is refused: it does not match its contents list
When one station updates another, it can send only the part of the package that station uses, and the station receiving it checks that part against the package's list of contents. A cut-down package that does not pass is refused: it was made for another station, or for this one before its system changed; its list or a file in it was altered or its signature does not match; it is too large; the station cannot read such a package at all; or the file changed while it was checked. Nothing was installed and the station is as it was, and the station's own reason is shown under the message. Upload the full update package, as published on the update server, or update the station from the update server. A station sending the update to another one never shows this: when the other station refuses the cut-down package, it sends the full one by itself.
The update server is unreachable
The station downloads its own firmware, so an update works when the station has internet and the
tablet does not; the reverse works too, since the browser can fetch the file and upload it. With
neither, download the .tar.gz elsewhere and upload it on the file tab. Under Help > Resources
every card that cannot list a download still links to the update server's own page for it.
When the station itself cannot reach the server, the note says why, after On this ground station. Quote that sentence in a report - it names the cause:
- Could not look up the update server's name - the station could not turn the server's name into an address: the network it is on does not let it reach a name server, or the station has no uplink at all.
- No route to the internet - the station has no way out: check its uplink (Ethernet, WiFi or modem).
- The update server did not answer in time - the link is too slow, or something on the way drops the traffic.
- The update server refused the connection - something on the network turns the connection away, often a firewall.
- The update server's certificate was refused as expired or not valid yet - compare the station's clock shown in the message with the real date: a clock far off it makes a valid certificate look expired.
- The update server's certificate was refused (without "as expired or not valid yet") - the station was shown a certificate it does not trust, often from a network that puts its own sign-in page in the way.
- The connection to the update server was cut off or The secure connection to the update server failed - something on the network broke the connection, often a network that filters traffic or asks for a sign-in page first.
- The update server answered with an error (HTTP ...) - the station reached the server and the server itself could not answer: try again later, and quote the number in a report.
The device asks for a root password
If the camera, or a Luckfox, refuses the update's login, the update stops before it changes anything and a dialog asks for the device's root password. Enter it and the update starts again; tick Remember on this station to keep it on this station for the next updates. "That password did not work" means the device refused the one you typed.
The device needs a new firmware image
A software update replaces Sokil but keeps the kernel from the firmware image. On a Luckfox camera and on a ground station that runs from an SD card, it also brings ZeroTier and the WiFi drivers current - the drivers only when the device still runs the kernel its image came with; they take effect after the next restart. On an IPC camera, the drivers and ZeroTier stay the image's. Reflash required means a known image, driver or ZeroTier fix is missing even if Sokil itself is current: update the software first, and reflash if it stays. Settings show, beside the Sokil version, the Image, the running ZeroTier version and the WiFi drivers build - marked "after restart" when a newer one is installed and waits for the next restart, and "from image" on a Luckfox still running its firmware image's drivers. Older devices that do not provide these values show no guessed age.
For an IPC camera, open Update firmware > Reflash firmware image in the camera's controls
(an amber dot on Update firmware means a reflash is due), or select the Reflash required
badge. The dialog shows the image the camera runs now beside the one it will run after the
reflash, and opens on the latest release of your channel; the channel is named above the list.
A release the station already holds is marked On this station: select it and choose Reflash
to that version. For any other release choose Download and reflash: the station downloads the
image, then asks whether to reflash the camera now, and Not now keeps the image on the station
for later. Download only downloads without asking, for a reflash later in the field without
Internet. The version you select is the version flashed: if the station holds another image by
then, it refuses and nothing is written. With an offline station, open the Upload a file tab
and supply the published archive and its .minisig signature; the release version fills itself
in from the signature, and once it is uploaded the dialog asks whether to reflash. The archive may carry any name on your computer - a second download saved as
(1).tar.gz is fine. An unsigned archive is refused, and so is an archive or a version that is not
the one the signature was made for, with the reason in the dialog.
Check the camera name, address and version in the confirmation. Land and disarm first; no power-cycle is needed. The station transfers and verifies the complete image before writing it and preserves settings, binding and the ZeroTier identity. The interface blocks reflashing when the selected camera reports the aircraft armed. If the armed state is unknown, it asks you to make sure the aircraft is disarmed; verify that yourself before confirming. If the station cannot be sure of enough time to watch the camera restart, nothing is written. After the reboot the station confirms the camera runs the new image. ZeroTier may be off; changes to settings during reboot do not turn a successful flash into a failure. Video and control are unavailable during the operation. A downgrade or a request to clear settings is refused. There is no rollback. Keep the camera and the aircraft powered until the update finishes. If power is lost while the image is being written, the camera will not start again and can only be recovered over UART. Loss of the transfer before writing leaves the installed image intact.
Luckfox is not supported by this remote IPC flow; use its USB flashing procedure. On a ground station, an old ZeroTier or a driver warning goes away with a software update; if it stays, the station needs a new SD-card image, not an IPC image. The guide for the device describes local flashing. If the result cannot be verified, inspect the job log and the device before retrying; a missing status response is not evidence of success. If the start response is lost or another camera job is running, Watch it shows the station log without claiming that job's result as the outcome of your request. A reflash takes several minutes. The dialog names each step in your language and shows a running timer, so a bar that holds still for a while does not mean the job has stopped. Until writing starts, a note says the reflash takes several minutes and not to switch off the camera or the aircraft until it finishes. From the flashing stage through reconnection, the warning says to keep the aircraft disarmed and powered until the camera restarts; it does not appear while preparing or transferring the image. Neither appears while watching a job that only stages firmware on the station.
Reflash an IPC camera over Ethernet
Remote image reflashing works over Ethernet or ZeroTier. It is blocked through the WiFi tunnel: a new image can change the radio driver or tunnel behavior and leave the camera unreachable. Downloading an image to the station is still available while inspecting a tunnel camera.
- Disarm the aircraft; no power-cycle is needed. Keep stable power connected to the camera, aircraft and station throughout the operation.
- Connect the camera's Ethernet port to the station, using a USB Ethernet adapter on the station if needed. Some camera boards expose Ethernet pads instead of a socket: use the board's wiring instructions and a suitable adapter. Do not connect power to Ethernet data pads.
- Use the camera's configured Ethernet address. The defaults are
10.1.1.40for the camera and10.1.1.30for the station; both ends must be on the same subnet. Keep the existing camera binding and radio settings. Open the station UI on its normal port, not the camera/repeater proxy ports8502or8503. - In the device inspection selector, choose the camera by its Ethernet address. If missing, scan for
devices or have an administrator add the address manually. Do not select
10.5.0.2or10.5.0.3. - Open Update firmware > Reflash firmware image, select a firmware release and choose Download and reflash, or Reflash to it when it is already on the station. Without Internet, upload the signed firmware archive and its signature on the Upload a file tab instead.
- Check the device name, Ethernet address and version in the confirmation, then confirm. Keep power and the cable connected until the station reports completion after the reboot.
- Check the image and ZeroTier versions beside the Sokil version in settings, and the camera configuration and connectivity before returning it to service.
A reflash changes the firmware image only; when it finishes the dialog offers to update the camera software as well.
If the operation fails or its result is unknown, inspect the log and reconnect over Ethernet before trying again. If power is lost while the image is being written, the camera will not start again and can only be recovered over UART.
The station shows Outdated, or the drone does
Software age runs both ways. The selector's Outdated label and the diagnostics finding are buttons that start the update for the box they name, and they work in pilot mode. A drone newer than its station raises its own finding on the station's diagnostics - This ground station's software is older than ... Update the ground station so both sides run the same release.
Selecting a device that is behind raises a dialog offering the update, with Continue anyway beside it. Nothing refuses control on a version alone, so an outdated camera still flies while you decide.
An IPC camera that also needs a new firmware image shows only Reflash required: after the reflash is verified, the station offers the software update as the next step.
A feature is missing and requests answer 404
The station's web server is older than the interface it is serving. Update the ground station.
A camera cannot be rolled back
Deliberately not built: a camera update is an overlay with no record of what the previous one held. Keep the camera's parameters file and re-flash if a camera update goes wrong.
An update seems stuck, or the page was reloaded during one
An update runs on the station, not in the page. Closing the tab, reloading it or losing the tablet's connection does not stop it. The station runs one update of its own, one update of another device and one camera job at a time.
- Reloading the page brings the update window back on the running update, with its log from the first line. It does not open over the fly view, the map or the video wall - it opens on the first other page you go to.
- Pressing Update firmware again while that update runs shows the running update instead of starting a second one. Nothing is uploaded or downloaded again.
- A window opened this way has a Hide button. Hiding it stops nothing; press Update firmware again to see it.
- If the station is already updating another device, the window shows that update, and its log says the device you pressed was not started. Start it again when the first one finishes.
- A camera update found this way opens as running with its outcome unknown; Watch it follows the station's log.
Over the radio an update is slow and the bar is the honest measure: a drone's update crosses the link a percent at a time and can take from a few minutes to most of an hour. The window waits as long as the log keeps moving, and gives up only after a long stretch with no new line at all. If the bar has not moved for many minutes, look at the radio link before you retry - a retry over the same link fails the same way.
The video stopped during an update and did not come back
An update stops the video the box itself produces for as long as the copy takes, because the link carries the update much faster with the streams off, and switches it back on at the end. Two lines in the update log say that switch-back did not confirm: "Video could not be restored now - the camera puts it back at its next boot" (Luckfox in place of the camera on that board) and, on a ground station, "Produced video did not restore through the API; restarting core to apply the saved restore list".
Nothing is lost either way. Power-cycle the camera and the video comes back with the settings it had. A ground station does not wait for that: it restarts its own core and puts its video back itself - which is what the second line is announcing, and why a station usually has its picture back before the update dialog closes. Only streams that were on before the update are ever switched back on, so something you switched off yourself stays off.
A box on a release of 2026-09-17 or newer ends the pause by itself when the update finishes, and the two lines above only appear on a box older than that.
Over the radio the pause is what makes the update practical, so a drone's picture going dark while its update crosses the link is expected. A camera pauses its video for the copy. A drone that is a ground station at heart pauses it while the package crosses the link, if its software is from 2026-09-17 or newer; an older one keeps its video on for that update, which is then slower, and pauses only for its own install. Either way the video comes back when the update ends, or - if the upload fails - as soon as the station gives up.
If the picture is still missing after a power cycle, the restore is not what went wrong - read the Camera and video source and Video in the browser blocks.
Flashing a Luckfox from Windows: the board never appears
The firmware zip's flash.bat installs the Rockchip driver itself and then waits for the board in
Maskrom mode; when the wait runs out it prints what Windows saw. No Rockchip USB device at all is
the cable or the BOOT timing: use a data cable, hold BOOT, plug in while holding, release, and run
the script again - retrying is always safe. A device Windows lists without its driver is the driver
store: run flash.bat -ReinstallDriver, or run flash.bat as administrator if adding the driver
was refused. Windows on ARM has no Rockchip driver and cannot flash the board - use a 64-bit or
32-bit Windows 10 / 11 PC, or Linux. The whole procedure is in
WiFi camera on Luckfox.