<a id="troubleshooting-camera"></a>

### Camera and video source

The camera has no settings page of its own. Its settings live in the interface of the station it is
bound to - select it in the device selector and every VTX settings tab is its. A camera on a bench
with no station is reached over Ethernet from a laptop running the station software: it answers at
`10.1.1.40` in the selector of `http://127.0.0.1/`.

There is one small exception, and it is a shortcut rather than a settings page. With a WiFi camera
selected, and only while you have the station's interface open on its plain address (port 80), the
device selector grows an **Open camera web UI** link - the station forwards the camera's own web
interface over the radio link on port **8502**. A repeater's is the same idea on port **8503**
(**Open repeater web UI**), and a repeater whose software is too old does not answer there - update
it. Neither link appears when the interface is open on any other port.

<a id="troubleshooting-camera--the-picture-turns-pink-in-flight-a-restart-clears-it"></a>

##### The picture turns pink in flight; a restart clears it

The camera module's IR-cut filter has stuck half way. It is a glass filter that a small mechanism
swings in and out in front of the sensor, and vibration or water stops it moving - the module's
hardware, not the encoder, the link or the station. Balance the propellers (a chipped propeller is
the trigger reported from the field), keep water off the module, and restart to clear it for the
flight. A camera that keeps doing it needs its module replaced.

There is one thing on the camera worth ruling out first on a hand-wired board, or one that had a
configuration file loaded onto it: the filter is driven by two GPIO pins, and wrong pin numbers or a
wrong polarity park it. Those three rows - **IR-cut pin 1 (GPIO)**, **IR-cut pin 2 (GPIO)** and
**Single-pin IR-cut inversion** - are on the streamer's **Night mode** tab under **VTX settings >
Streamers** (expert), and they take effect at the next restart. Setup writes the board's own values.
A unit nobody has touched there, which clears on a restart, is the mechanism and not a setting.

<a id="troubleshooting-camera--one-band-of-the-frame-is-sharp-and-the-rest-is-blurred"></a>

##### One band of the frame is sharp and the rest is blurred

A lens or sensor fault on that one camera - a decentered or tilted lens, or a sensor not seated
square - tilts the plane of focus across the frame, so the bottom is sharp and the top soft, or the
other way round. No preset, zoom, night mode or bitrate setting moves it, and a torn frame on a
lossy link is a flicker, never a fixed band. Inspect the lens seating and focus, try a known-good
lens or module, and treat it as one bad camera rather than a fleet problem.

<a id="troubleshooting-camera--the-frame-rate-drops-at-dusk-or-with-something-close-in-front-of-the-lens"></a>

##### The frame rate drops at dusk, or with something close in front of the lens

In low light, night mode can lengthen exposure enough to reduce the frame rate. On the streamer's
**Night mode** tab under **VTX settings > Streamers**, reduce the adaptive maximum level if motion
blur or frame-rate loss is excessive. The expert **Min. shutter (µs, 0=auto)** (parameter `vtx_eye_night_min_shutter_us`) row sets a minimum
exposure time, not a maximum: raising it prevents shorter exposures. At startup, 0 becomes one
configured frame period; applying 0 live leaves the current shutter floor unchanged. Adaptive
night mode can still lengthen exposure beyond that baseline.

A dark object filling the frame can trigger the same response; this is a field report, not a
measured result. See [video quality](video-quality.md#video-quality) for the day and night controls.

<a id="troubleshooting-camera--the-night-picture-is-washed-out-white-and-never-recovers-or-day-never-comes-back"></a>

##### The night picture is washed out white and never recovers, or day never comes back

Night mode on a Sigmastar camera is locked in: once the scene has gone white it no longer looks like
daylight to the camera, so night mode does not end by itself. The fast exit is built for exactly this - the share of bright pixels that forces night off
(**Fast exit** (parameter `vtx_eye_night_hist_top_exit_pct`), default 20, 0 = off) - so a camera stuck white has that lever
off, set too high, or its delay too long. **Fast exit** and its debounce are on the streamer's
**Night mode** tab under **VTX settings > Streamers**; **Restart > Sokil** on the camera ends the
current episode.

<a id="troubleshooting-camera--the-picture-breaks-up-over-grass-at-takeoff-and-is-fine-in-the-air"></a>

##### The picture breaks up over grass at takeoff and is fine in the air

Moving grass is more detail than the lowest bitrate can carry. Go one step up the preset ladder on
**VTX settings > Presets**, or raise the bitrate of the slot you take off on; the
[video quality](video-quality.md#video-quality) guide has the ladder.

<a id="troubleshooting-camera--the-picture-flips-between-two-aircraft-several-times-a-second"></a>

##### The picture flips between two aircraft several times a second

Two bound aircraft are transmitting to the same station at once, and usually only one of them is
flying - the other is sitting on the ground with its power on: a spare, one that has just landed,
one being prepped for the next sortie. A camera sends video from the moment it boots, whether or not
its aircraft is in the air, and only the one the station names as active is meant to keep sending -
every other one goes on standby. With two of them sending, both streams arrive on the same port and
interleave, so the station decodes frames from each in turn and the picture alternates between the
two aircraft; pilots read it as a blink, or as one drone turning into another. MAVLink travels the
same way, so the telemetry can jump between the two as well. A station that receives over the
network only (its WiFi radio off) keeps the two pictures apart instead with current software, and says
so in Diagnostics - the next block; with the station's WiFi radio on, or on older station software,
the picture flips as described - on the UFEC WiFi radio when one of the two arrives over the network,
because a second camera on the same radio link is refused (the next block).

Select the aircraft you are flying in the **Active vehicle** picker, or press **Take control** on the
standby banner over the video - the other camera stops transmitting and the picture settles. Cutting
power to the aircraft that is not flying does the same thing.

Three cases leave both cameras transmitting, and they are what to check when selecting an aircraft
does not settle it: a camera that sends nothing over Ethernet or ZeroTier is never put on standby, by design,
because its WiFi link is point-to-point with its own station - a WiFi camera that also sends something
over Ethernet or ZeroTier (its video, or only its MAVLink) stands by like any other once the station reaches it there, but only on
camera software from 2026-09-23 or later; a camera that has been made exempt always sends, which
is what a multi-camera payload feeding one board needs; and a station that is off, unreachable or on
software too old to name an active vehicle sends no verdict at all, so every camera reverts to
transmitting - the common way two aircraft end up interleaved.

**A recording made while this was happening cannot be repaired.** Both aircraft went into the file as
it was written, so playback shows the same flipping and exporting it again will not separate them.
Record again once only one camera is transmitting.

<a id="troubleshooting-camera--diagnostics-says-more-than-one-camera-is-sending-video-to-this-station"></a>

##### Diagnostics says more than one camera is sending video to this station

The warning names the video stream and the address of every camera sending on it. It is the case
above - two cameras transmitting to one station at once - wherever the station can tell there are
two. A station that receives over the network only also keeps the two apart: it shows one picture,
from the camera it controls whenever that camera is sending, and the other camera's video no longer
mixes into it. On the **UFEC WiFi radio** a second camera on the same radio link is refused by the
station: only one camera is received and counted there, so the picture does not flip and this warning
does not appear - but the other camera still transmits and still takes up airtime on the channel. With
one camera arriving over the radio and another over the network the station counts both and warns, but
cannot keep them apart - the picture can flip as described above - and the camera it hears over the
radio is listed as the radio. Either way the other camera costs you capacity on the link.

**Tools > Link test** on the selected camera measures that camera's own loss, apart from the other
camera's, and says how many other cameras the station also receives.

Two things keep a second camera sending:

- **Always send video** (parameter `vtx_ctl_exempt`) is on for it (**VTX settings > Connection > Link
  transport > Over IP > Ground station**). That switch is for a multi-camera payload feeding one
  board; on an ordinary aircraft leave it off.
- It does not hear this station's **Active vehicle** selection: it has no way back to this station,
  it has only just started, or its software is too old to follow the selection
  ([Software compatibility](compatibility.md#compatibility)).

Select the aircraft you fly in the **Active vehicle** picker so the other camera goes on standby,
switch **Always send video** off on the other camera if it is on, or power the other aircraft off.
The warning clears once only one camera is sending.

<a id="troubleshooting-camera--4k-or-2592x1944-is-not-offered-on-an-ssc30kq-camera"></a>

##### 4K or 2592x1944 is not offered on an SSC30KQ camera

The picture on an **MC-L12B**, a **MINIIPC 19x19** or a **SkyPulse IP** stops at **2560x1920**, and that is the
hardware, not a setting. The SSC30KQ chip is rated by SigmaStar at 3K (3072x1728) and has no 4K mode
at all, where the SSC338Q boards are rated 4K; and the IMX335's all-pixel 2592x1944, which Sony's
datasheet and the module's own spec sheet both quote, sits only in the driver's HDR branch, which is
not exposed at all - the mode list the camera really offers tops out at 2560x1920. So the Resolution
row of the camera's **Sokil Eye** card and the mode dropdown in the preset ladder end there, and the
setup wizard plans no 4K rung.

**If a 4K rung is offered on a board you know is an SSC30KQ, the board pick is wrong.** A camera on
a release older than 8 September 2026 reports its chip as `ssc338q` whatever it is, so on such a box the wizard's **Board** step lists
all six IPC boards and your pick is the only thing that says which one this is. Run
[Setup](http://10.1.1.30/cam/setup) (admin) again and pick MC-L12B, MINIIPC or SkyPulse IP on that step, or update the camera,
after which it names its own chip and is offered only the three SSC30KQ boards. The same pick lives on
the [Hardware page](http://10.1.1.30/cam/hardware) (admin), which carries that layout switch.

A value the camera already holds stays in its picker so a unit somebody set higher can be lowered.
[WiFi camera on an IPC board](camera-wifi-ssc338q.md#camera-wifi-ssc338q) has the whole ceiling.

Diagnostics also says "resolution above what the camera board can capture" when a **Sokil Eye**
**Resolution**, or a preset's resolution, is set above a board's limit; a Luckfox camera, for one,
stops at 1920x1080 ([the limit](camera-wifi-luckfox.md#camera-wifi-luckfox--what-setup-asks-and-writes)). Video
still runs, but Sokil caps the request and streams at the board's limit, so the settings show a size
that is not in effect. The cap is a safety limit and not a preference: asking such a board for a bigger
frame hangs the whole chip until the power is cycled. Lower the Resolution on the **Streamers** tab of
VTX settings, or the preset's row on the **Presets** tab, to the size the finding names. On such a
board presets can change bitrate and error correction, but not resolution.

<a id="troubleshooting-camera--the-resolution-stays-at-768p-whatever-i-set"></a>

##### The resolution stays at 768p whatever I set

A configuration file that left a zoom set. The zoom is the stream's **Digital zoom** (parameter `vtx_eye_zoom`), in tenths, and 10 is 1.0x -
anything above it is zoomed in - while the default zoom strategy (**Digital zoom strategy** (parameter `vtx_eye_zoom_mode`), an expert's row, on **Reduce
resolution**) shrinks the encoded frame to the crop instead of upscaling it, so the picture arrives smaller
than the resolution row says (on an Infinity6C camera, only past the video mode's zoom limit). Put the zoom back to 10, or run setup on the camera, which writes it
from the board's own defaults and carries no stray zoom. If you must load a file, take its zoom rows
out first. If the zoom comes straight back on its own, no file put it there and the block below is
the one you want.

<a id="troubleshooting-camera--the-picture-is-zoomed-in-about-2-2x-and-typing-a-zoom-changes-nothing"></a>

##### The picture is zoomed in about 2.2x, and typing a zoom changes nothing

**Absolute zoom** (parameter `rc_act_vtx_zoom_sw`) is assigned to channel 8 by default and continuously
follows its position. With **Maximum zoom** (parameter `vtx_zoom_max`) at its default 4.0x, a channel at
1500 gives **2.2x**. This can be a live handset channel with no switch assigned, or Betaflight's
fallback before it has received the handset. **Preset cycle** (parameter `rc_act_vtx_preset_sw`) on channel
9 likewise follows the channel position and can select a middle preset.

Select the camera and open **[Control](http://10.1.1.30/cam/control-settings) > RC Actions** to check the channel's
live value. For an unused live channel at 1500, either assign a real control on the handset or clear
**Absolute zoom** to `0`. Clearing the assignment enables manual entry in **Sokil Eye > Digital
zoom** (parameter `vtx_eye_zoom`); while assigned, the RC channel keeps control.

For Betaflight's fallback values, connect the flight controller by USB and open **Flight controller
setup > Receiver > Failsafe**. With the station's control camera receiving RC over MAVLink, the page
compares the bound AUX channels with the camera's policy and lists current and wanted settings.
**Apply camera policy** applies only the differences after confirmation, then saves and reads back.
The overview notice links to this tab. An unknown or unreadable camera means the policy cannot be
checked. See [Betaflight setup](betaflight-setup.md#betaflight-setup--failsafe) and
[RC channel plans and switches](channels-switches.md#channels-switches) for the fallback policy and CLI alternative.
This changes signal-loss fallback values; it does not change a live handset channel idling at 1500.

<a id="troubleshooting-camera--settings-on-the-camera-revert-as-soon-as-i-save"></a>

##### Settings on the camera revert as soon as I save

The camera's software is older than the interface. A device drops a key it does not know without a
word, so a row for a setting this firmware never had reads back its old value after every save.
The camera's status strip carries a red **Outdated** label for exactly this, and the label is a
button that starts the update; selecting such a device also raises a dialog that offers the update
and lets you carry on regardless. If the camera is current, check which device is selected: the
value a row shows after a reload is the device's own.

<a id="troubleshooting-camera--the-second-video-stopped-after-the-camera-s-address-changed"></a>

##### The second video stopped after the camera's address changed

The second streamer's **Send video to** (parameter `vtx_eye2_host`) row is on its **Pipeline** tab under
**VTX settings > Streamers**, and it is an expert row because on a normal kit it has nothing to say:
it ships as a template that resolves to the camera's OWN local address, which hands the picture to
the camera's own link rather than sending it to a station. A literal address typed there by hand is
what breaks - it does not follow an address change, and nothing says so. Put the template back, and
check that the second video is switched on on the station's receive side.

<a id="troubleshooting-camera--a-thermal-camera-on-usb-drops-out"></a>

##### A thermal camera on USB drops out

The USB lead to a thermal core is sensitive: keep it short and shielded, and feed the hub and the
core from the board's BEC rather than the board's USB rail - the radio stays on its own BEC, because
a radio card and a thermal core on one feed brown each other out. [Power and the BEC](power-bec.md#power-bec) has the rule.

<a id="troubleshooting-camera--the-microphone-is-on-but-there-is-no-sound-on-the-ground"></a>

##### The microphone is on but there is no sound on the ground

Prove the camera first, on the camera. On **VTX settings > Streamers** open the streamer and its
**Audio** tab: the **Input level** (parameter `vtx_eye_aenc`) row reads a level in dBFS and **50 pkt/s** while the encoder is
running, and it is measured on the aircraft, so it answers with no ground station in front of it.
**No audio flowing** there means nothing is being produced, and nothing on the ground can fix that.
Set **Microphone** to **Test tone (no mic)** to take the microphone itself out of the question.

If the camera is producing sound and you still hear none, the rest is on this device: an amber
speaker saying *Audio is waiting - tap to enable* is the browser's autoplay rule, and **Main stream
audio** / **Second video audio** in the **Playback (this device)** card can simply be off. A red
note on the Audio tab means the camera has no Opus library and cannot encode sound at all.

One trap: with **Silence suppression** (parameter `vtx_eye_audio_dtx`) on (an expert row on that same Audio
tab) an idle microphone sends nothing and the packet rate falls to zero, which reads exactly like a
dead microphone. Turn it off while you are diagnosing.
[Microphones and audio](audio.md#audio) has the rest.

<a id="troubleshooting-camera--there-is-no-microphone-input-on-a-luckfox-camera"></a>

##### There is no microphone input on a Luckfox camera

The chip has one - a proper analog microphone input with its own bias - but the board routes those
pins to no header, and the vendor's own documentation offers audio only on a different model in that
family. So sound on a Luckfox means a **USB microphone**, chosen by its sound-card name in the
**Microphone** row of the streamer's **Audio** tab under **VTX settings > Streamers**. The documented Luckfox configuration uses **48000 Hz**; supported rates depend on the microphone and audio driver.

Luckfox firmware also shipped for a while with no Opus library. Such a camera says so in red on that
tab and cannot encode sound at all - update it.
[Microphones and audio](audio.md#audio) has the per-board table.

<a id="troubleshooting-camera--nothing-tells-me-the-microphone-is-dead"></a>

##### Nothing tells me the microphone is dead

Nothing does. There is no diagnostics finding for audio anywhere - not on the Diagnostics page, not
on the Status flow board - so a microphone that died in a hard landing is silent evidence only.

Three surfaces are what you have instead: the **Input level** meter on the camera's Audio tab, the
small speaker the video pane's status strip grows as soon as its stream carries any sound, and the
red ring the video wall draws on a tile that is making a noise. Check the meter before a flight, the
way you check the picture - [Microphones and audio](audio.md#audio) has the bench levels to
compare against.

<a id="troubleshooting-camera--a-cmd-streamer-has-no-command-or-will-not-start"></a>

##### A CMD streamer has no command, or will not start

The **CMD Streamer** and **CMD Streamer 2** cards on **VTX settings > Streamers** run whatever
command is typed into their text field (placeholder *Streamer command*); the switch in the card
header enables the card. Diagnostics reports *has no command to run* the moment the switch is on and the
field is empty - fill the field or switch the card off - and *could not start* when there is a
command but the process is not running: check the command, then the external camera it reads
from. A CMD streamer that crashes and restarts in a loop can escape both findings - a process that
is respawned quickly always looks alive when Sokil checks it - so if
the picture comes and goes with no finding, watch the card's own state instead.

<a id="troubleshooting-camera--sokil-eye-is-running-but-its-rtsp-camera-is-not-answering"></a>

##### Sokil Eye is running but its RTSP camera is not answering

An eye with its **Source** set to an RTSP camera (RTSP and RTSP passthrough alike) reports its
output only while packets actually move; after a few seconds of nothing Diagnostics
raises *the RTSP camera it reads from is not answering*. The eye is fine - the camera stopped
feeding it. Check that the camera is powered and reachable at the address in the **RTSP URL** row
of the eye's card on **VTX settings > Streamers**, or that *Auto (from camera host)* points at the
right host. A camera on another subnet with no route to it looks exactly like this. Its row on the
**Streamers** tab reads **No video** rather than **On air**. An eye used for computer vision only,
with its stream switched off, never raises this.

<a id="troubleshooting-camera--a-picture-is-frozen-and-diagnostics-says-the-camera-device-is-gone"></a>

##### A picture is frozen and Diagnostics says the camera device is gone

A USB camera can drop off the bus while the aircraft is running, and the board then has no device
left to read: the picture from the streamer that was reading it freezes on its last frame or goes
black. On a camera with a second streamer that picture carries on as if nothing had happened; on a
camera with one, the whole picture is gone. Diagnostics raises this per streamer either way, and the streamer's row on the **Streamers** tab reads **No video**. On the bench a Sigmastar camera
running a MIPI sensor and a USB camera side by side did this several times in about an hour,
and the frame rate from the USB camera decayed for minutes before each one.

Diagnostics raises *has lost the camera device it reads from* against the streamer that lost it, so
the frozen picture is labeled rather than a mystery. The camera keeps reopening the device by
itself and the picture comes back on its own in roughly ten to thirty seconds; the finding clears
with it.

**What to check** when it does not clear, or when it keeps coming back: the device's lead and both
its connectors, its socket, and the power the device is fed from. When a camera drops out
repeatedly, look at its lead and its supply first -
[Power and the BEC](power-bec.md#power-bec) has the rule for feeding one. Swapping the device for
another of the same kind is the cheapest way to settle whose fault it is.

**What not to do.** Restarting the camera software does not put a USB device back on the bus, and
on some cameras running two streamers at once every start and stop of one of them interrupts the
other one's encoder, so a restart aimed at the frozen picture interrupts the working one. Sokil therefore
leaves the streamer running and waits, on purpose. There is no setting that fixes this one.

On older camera software this finding does not exist at all and the frozen picture stays
unlabeled. A missing finding means the camera cannot say, never that the camera is fine.

<a id="troubleshooting-camera--sokil-eye-refuses-its-configuration"></a>

##### Sokil Eye refuses its configuration

Sokil Eye is running but has refused its configuration: this combination of settings cannot run on this board. It waits for the settings to change before trying again. Check the affected **Sokil Eye** card on the **Streamers** tab of **VTX settings**, especially the source and the video format supported by the camera. Correct the settings; if the message remains with supported settings, update the device software and contact support.

<a id="troubleshooting-camera--sokil-eye-never-comes-up-and-diagnostics-says-it-cannot-start"></a>

##### Sokil Eye never comes up, and Diagnostics says it cannot start

The streamer behind a **Sokil Eye** card stops the moment it is started, every time, so it never
sends a picture. Diagnostics raises *cannot start* against that streamer, and says why when it can:

- **a library the device's software is missing**, named in the finding (for example
  `libswresample.so.4`) - the device's software is incomplete, and nothing in the settings or on
  the camera side can make up for it. This is the usual case, seen on a station whose software
  image shipped without some of the libraries the streamer needs;
- **an exit code or a signal** - the streamer starts and stops on its own before it is up. On
  some camera boards a missing library shows up this way too, so the update below is worth trying.

The device keeps trying to start the streamer by itself, and the finding clears as soon as one start
comes up. While it stands, it takes the place of the plainer *could not start* and *keeps crashing
and restarting* findings, because both of those send you to the streamer's settings.

**What to do.** Update the device's software: the update installs what the streamer needs, and the
streamer is tried again once the update is in. If the device is already up to date and the finding
stays, reflash it with a current image - [The device needs a new firmware
image](troubleshooting-updates.md#troubleshooting-updates--the-device-needs-a-new-firmware-image). For an exit code or a
signal, first check the camera connection and the streamer's settings on its card on **VTX settings
> Streamers** (switching the card off and on tries again at once), then update. If the finding is
still there after an update or a reflash, [contact support](troubleshooting-getting-help.md#troubleshooting-getting-help) with
the finding's text.

On older device software this finding does not exist, and the same fault shows as *keeps crashing
and restarting*.

<a id="troubleshooting-camera--majestic-or-sokil-eye-will-not-start-because-a-process-still-holds-the-encoder"></a>

##### Majestic or Sokil Eye will not start because a process still holds the encoder

A camera board has exactly one video encoder, and exactly one program may own it at a time. When
you switch from **Majestic video** to a **Sokil Eye** card on the Streamers tab of VTX settings, or
back the other way, Sokil stops the old one and waits for it to let the encoder go before it starts
the new one. That is why a changeover can take a second or two with no picture, and it is
deliberate: on the Sigmastar camera boards starting the second one early resets the whole camera
chip, and then nothing comes back until the power is cycled anyway. The wait itself is on every
camera board - the Sigmastar is the reason for it, not the condition.

Diagnostics raises *is deliberately kept off* against the streamer that is waiting, and it names
the process that still holds the encoder. That wording is the whole message: the streamer did not
fail to start, it has not been allowed to.

**What to do.** Do not wait this one out - the waiting is already over by the time you see it. On a
healthy changeover the finding never appears at all, because the old program lets go well inside the
wait; the camera raises it only once the hold has outlasted that. What you are looking at is almost
always the old program stuck in the camera's driver, no longer answering anything, so the one thing
that ends it is getting that process off the camera: **switch the camera's power off and on again**.
Nothing in the settings will move it, and there is no second gesture to try.

**What is not wrong.** The ribbon cable between the sensor and the board, the streamer's own
settings, and the camera the streamer reads from. All three are what the plain *did not start*
findings send you to look at, and none of them is what is happening here - which is why this
finding is worded differently and says so.

If it keeps happening on one camera after a power cycle, that camera's encoder is wedging under
load and the settings that drive it are the place to look: lower the resolution and the frame rate
on the streamer's card and see whether it settles.

<a id="troubleshooting-camera--majestic-is-switched-on-but-a-sokil-eye-is-holding-the-encoder"></a>

##### Majestic is switched on but a Sokil Eye is holding the encoder

A camera board has one video encoder and one owner for it, so **Majestic video** and a **Sokil
Eye** card cannot both run. While any Sokil Eye card is switched on, Majestic is held off: it does
not start, however long you wait. Diagnostics reports that as a warning against Majestic and names
the Sokil Eye that is holding the encoder.

Nothing is down. The picture is coming out of that Sokil Eye, and the kit is flying on it. What
the warning says is that both switches are on, that one of them is on by mistake, and that
Majestic is never going to come up while it stays that way.

**What to do.** Open [VTX settings > Streamers](http://10.1.1.30/cam/vtx-settings?tab=streamers), decide which of
the two you want, and switch the other one off: the **Majestic video** card's own
switch (parameter `vtx_majestic_enabled`), or the **Sokil Eye** card the finding names (parameter `vtx_eye_enabled`).
That is the whole fix, and it takes effect at once.

**What is not wrong, and what not to try.** The ribbon cable between the sensor and the board is
fine - that is what the plain *Majestic is not running* finding sends you to look at, and this is a
different finding for a different reason. Waiting is no use, and neither is a restart or a power
cycle: the camera works this state out from the two switches continuously, so it comes straight
back exactly as it was. That is the difference from the hold above, where what has to go is a
process the camera cannot shift.

<a id="troubleshooting-camera--the-camera-sends-one-resolution-and-the-streamer-is-set-to-another"></a>

##### The camera sends one resolution and the streamer is set to another

Only an eye fed by another device's stream (an RTSP or UDP source) can see this; a sensor the
board reads itself is always the size it was asked for. Three cases hide behind one finding.
Where the board can rescale, the frames are resized to the **Resolution** set in the eye's card -
the picture works and the presets keep their meaning, at the cost of the resize. Where the chain
passes the stream through, the output follows the source and the configured resolution is a
wish nothing grants - the presets' resolution rung does nothing. Where the board can neither
rescale nor pass through, every frame is dropped and the stream is dead, and this warning is
the only thing that says why. In every case setting **Resolution** to the size the camera sends
ends it; leave it only in the first case, and only if you want the output size.

<a id="troubleshooting-camera--the-presets-drive-a-video-source-that-is-not-the-one-switched-on"></a>

##### The presets drive a video source that is not the one switched on

The preset switch changes the bitrate and quality of ONE video source - the camera picked in the
**Main video** row of the **Streams** card on **VTX settings > Streamers**. When no source that
is switched on is picked there, moving the switch changes nothing on the picture, and
Diagnostics raises one finding per source that is on. Pick the source that is on in that row -
the picker names them as their cards do (*Majestic video*, *Sokil Eye*, *CMD Streamer*).

<a id="troubleshooting-camera--the-ground-station-receives-another-video-source-than-the-main-video-row-picks"></a>

##### The ground station receives another video source than the Main video row picks

The source picked in the **Main video** row is switched on, but the picture the ground station
receives comes from another source that is on: a camera with two Sokil Eyes where the second eye
(often a USB camera) is picked while the first eye's picture is the one sent, or a laptop station
whose row still picks *CMD Streamer* while its own webcam's Sokil Eye is what streams. The video
presets keep driving the picked source, so moving the preset switch changes nothing on the live
picture; **Tools > Link test** measures the source the ground station actually receives and names
it. Pick that source - the one the finding names - in the **Main video** row of the **Streams**
card on **VTX settings > Streamers**. The finding waits a few seconds before it appears, so the
moment of a camera switch does not raise it.

<a id="troubleshooting-camera--sokil-eye-cannot-write-recordings"></a>

##### Sokil Eye cannot write recordings

Raised only while a recording is engaged, and re-checked regularly: the **Recording folder**
in the eye's **Recording** tab is empty, does not exist or is not a directory, cannot be written,
or is nearly out of free space. Set the folder to an existing, writable path on the card and check
the free space; leaving the folder field blank switches local capture off and, with a recording
engaged, is reported as this. There is no start switch in the eye's card - recording starts from the OSD's
**Record** button or the *Video recording* RC action. A vendor camera that records to its own SD
card (control set to SIYI or Topotek) needs no folder here; keep local recording off on it.